A new leak test method for enclosed cab filtration systems
Our rough guess is there are 8,250 words in this book.
At a pace averaging 250 words per minute, this book will take 0 hours and 33 minutes to read. With a half hour per day, this will take 1 days to read.
How long will it take you?
This book will take an estimated to read at a reading speed averaging words per minute. With 30 minutes per day, this will take to read.
Enter your reading speedYou can take one of our WPM reading speed tests to find your reading speed.
Create a free account to track your reading progress, build your reading list, and set reading goals.
Contributions
- National Institute for Occupational Safety and Health. Office for Mine Safety and Health Research - Contributor
Publication
2012 - Department of Health and Human Services, Public Health Service, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, Office of Mine Safety and Health Research, Pittsburgh, PA, Ohio
Language
English
Word Count
8,250 words, Guess
Page Count
33 pages
Identifiers
- Library of Congress Control Number2012494245
- OCLC Control Number798498145
- Open LibraryOL30748121M
Classifications
- LCCTN301 .N44 2012
Description
"A new test method has been developed by the National Institute for Occupational Safety and Health (NIOSH) and Clean Air Filter (CAF) for quantifying the outside air leakage into environmental cab filtration systems. This method uses specially configured filter cartridges to remove carbon dioxide (CO2) from the environmental cab's air filtration system. Real-time gas monitors are used to measure the outside and inside cab CO2 concentrations after the cab reaches steady-state equilibrium conditions inside an unoccupied cab. Cab filtration system leakage can be mathematically determined using the measured cab penetration (inside to outside cab concentration ratio) and the special CO2 filter cartridge efficiency. Examination of several CO2 sampling instruments for this type of testing showed them to be relatively precise, but exhibited noticeable variations in accuracy. These results indicate that frequent gas calibration checks of comparative sampling instruments would be needed to ensure their accuracy, which is not well-suited for cab field testing. Thus, a single-instrument, multiple-sample-location cab testing methodology was devised to eliminate multiple-instrument sampling biases and frequent calibrations during testing. This methodology was examined and can provide accurate measurements of filtration system leakage into enclosed cabs with a precise instrument at or near steady-state test conditions. The new leak test method provides cab manufacturers, cab service personnel, and industrial hygienists with a measurement tool to ensure environmental cab integrity and minimize worker exposure to outside airborne substances." - NIOSHTIC-2